- Online only
-
MenuBack
-
RO systems
-
Faucets
-
Water dispensers
-
Water softeners
-
Dynamizers
-
Off-grid water
-
Water testing
-
Deals
-
-
Refurbished RO systems
Tested and inspected RO systems for pure water at a reduced price.
See offersRO system + water softener pack
Complete protection with an RO system and a water softener.
Get 15% offRO system + hydrogen water generator pack
Combine reverse osmosis water and hydrogen-rich water.
Get 15% off
-
-
- PRO
- RENTAL
FREE SHIPPING
On orders of €150 or more within mainland France 
(home products only)
Ships within 24 hours
+33 3 66 88 17 85
Call us Monday to Friday,
9:30 am–5 pm (Paris time)!
Email: contact@josmose.fr
This small industrial RO system is the cheapest on the market!
- Production capacity of 200 to 400 liters of pure water per hour,
- up to 10,000 liters per day!
- Affordable price
Custom-made product — Right of withdrawal does not apply
This product is made or configured to order according to your specifications. In accordance with Article L221-28 of the French Consumer Code, the right of withdrawal does not apply to goods made to the consumer's specifications or clearly personalized.
Before placing your order: please check that this product meets your needs. Our team is available to advise you at 03 66 88 17 85.
Industrial RO systems: 5,000 to 10,000 liters per day
On this page, you will find all the essential information about our range of compact industrial RO systems. These models produce 5,000 to 10,000 liters per day of RO water.
For higher production capacity, we invite you to discover our industrial RO system from 200 to 1,200 L/h .
Customizing your industrial RO system
A configuration tailored to your water quality
To provide you with a custom machine perfectly suited to your needs, please send us the following water parameters:
- TDS or conductivity (ppm, mg/l or microS/cm)
- Free chlorine level (mg/l)
- Bacteria level
- Hardness (°f)
- Chloride level (mg/l)
Other parameters can also be useful:
- pH
- Temperature
- Turbidity
- Alkalinity
- Bicarbonates
- Carbonates
- Nitrates
- Sulfates
- Boron
- Calcium
- Magnesium
- Potassium
- Iron
- Manganese
- Sodium
- Lead
Need advice for your installation?
Our team can help you choose your industrial RO system and its pretreatments.
Request a quote+33 (0)3 66 88 17 85
Filtration stages in industrial reverse osmosis
How industrial reverse osmosis works
The heart of the system is an osmotic membrane that retains particles larger than 0.0001 micron.
Our membranes are 21 or 40 inches long and 3.9 inches in diameter. Their connectors are 1.05 inches long with a diameter of 0.75 inch.

Reverse osmosis membrane
The membrane is the central element of the system and separates the water produced from the water concentrated with the retained elements.

Options for your industrial RO system
Pretreatments to protect the membranes
To pre-filter your water and extend the life of your osmotic membranes as much as possible, several types of pretreatment can be offered depending on water quality.
Chlorine disinfection system
When the water contains a large amount of bacteria, upstream disinfection can be set up to limit their growth and protect the membranes. This is done with an ATHENA 2 AT-AM dosing pump.

25-micron pre-filtration
If the water to be purified contains significant debris such as soil, sand or rust, a 25-micron pre-filter can be installed upstream to limit fouling of the RO system.

Limescale treatment with a water softener
Limescale can quickly clog reverse osmosis membranes. We therefore recommend neutralizing it upstream with a salt-based or CO₂ water softener.
With a salt-based water softener, magnesium and calcium are replaced by non-scaling sodium. This solution requires a regular supply of salt and regeneration cycles.
CO₂ softening is a compact alternative with no drain discharge, based on converting carbonate into non-scaling bicarbonate.

Chlorine treatment with activated carbon
Chlorine is harmful to the membranes of an RO system. It must therefore be removed upstream with an activated carbon system.
The minimum capacity provided for the most demanding dechlorination cases is estimated at 150 to 200 m³ of treated water per kilogram of carbon.

Packaging and delivery
Protection suited to professional transport
Our industrial RO systems are delivered packed in a wooden crate to protect the equipment during transport. Shipping is made directly to you once we receive the balance of your payment.

Installation & Maintenance
Installation
Setting up your industrial RO system
Our factory works in partnership with the WQA (Water Quality Association) and is therefore able to install our industrial equipment anywhere in the world. In practice, most of our customers install the equipment themselves by following the complete user manual provided. We also offer phone support for setting up the equipment.
Maintenance
Replacing consumables
Filters and membranes must be replaced regularly to maintain system performance.
| Consumable | Replacement frequency | Product |
| PP filter | Every 3 months For 24/7 use |
Discover |
| Reverse osmosis membranes | Every 2 years For 24/7 use |
Discover |
Warranty
Manufacturer warranty and parts availability
The manufacturer's warranty is 2 years and covers your entire system under normal use.
After the warranty period, we commit to providing replacement parts at reasonable prices in case of failure.
Specifications
Technical Specifications
Technical data and performance
| Specifications | Values |
| Working pressure | 8 to 12 bar |
| Tubing diameters | Inlet: 3/4" (20/27) – Outlets: 1/2" (15/21) |
| Pre-filter height | 20" (50 cm) |
| Salt rejection ratio | 99% |
| Pressure gauge | Glycerin-filled pressure gauge |
| Flow meters | Inlet and outlet flow meters |
| High-pressure pump control | Start / Stop button |
| Pressure control | Pressure system control |
| Display | Instant display of filtered water conductivity |
| Flushing | Automatic flushing of the inlet feed flow |
| Control panel | Allen-Bradley digital control panel |
| Pump | NUERT rotary pump – cannot run for more than 8 consecutive hours |
| Frame | Stainless steel frame |
| Tubing | PVC tubing |
| Recovery rate | 50 to 60% – 1 liter of wastewater for every 1 to 1.5 liters of RO water |
| Normal operating condition | 1500 ppm |
Documents
Documents and downloads
Industrial RO system technical documentation