• Online only

This new industrial RO system is the most affordable model on the market, producing 400 to 800 liters of pure water per hour, up to 20,000 liters of RO water per day! It uses single-phase power and can operate 24/7 thanks to a vertical pump.

Delivery in 48 to 72 h for an additional 200 € excl. VAT.

QUBE-EX - Economical Industrial RO System 400 to 800 l/h

€4,300.00 HT

1. Membrane Capacity

2. Chlorine Disinfection

3. 25-Micron Pre-Filtration

4. Free Chlorine Treatment

5. Limescale Treatment

Your configuration
    Your configuration total tax incl.

    Need advice, information or a quote?

    Contact us directly by phone or email.

    Monday to Friday, 9:30 am to 5 pm (French time). Standard-rate call.

    Josmose stands behind every RO system delivered.

    • Delivery in 24 to 48 h, free from €150 in mainland France.
    • Payment in 3 or 4 installments, interest-free.
    • Phone support 5 days a week, 9:30 am to 5 pm (French time), before and after your purchase.

     

    Quantity
    Available in 1 to 2 weeks

    Installation & Maintenance

    Installation

    Starting up your industrial RO system

    Our factory works in partnership with the WQA (Water Quality Association) and can therefore support the installation of our industrial equipment worldwide.

    In most cases, however, you can install the equipment yourself by following the comprehensive manual supplied with it. Approximately 90 % of our customers install their systems themselves.

    We also offer phone support to help you start up your equipment.

    Installation tips

    Pre-filtration

    Installation is straightforward. Simply make sure you position the filter in an easily accessible location, since it will need to be replaced regularly.

    Chlorine dosing pump

    Installation is relatively simple, but you must adjust the pump carefully by following the manual. An insufficient dose may prevent complete elimination of bacteria, while an excessive dose may prematurely saturate the activated carbon and then damage the RO membranes once the carbon is saturated.

    Water softener

    Distribute the resin evenly between the two tanks to allow proper water circulation. The connecting arms between the two tanks must be glued into their connectors using high-strength PVC adhesive.

    Regeneration volume calculation:
    Resin volume in one tank × 5,000 / water hardness (°f)

    Installation of the CO₂ water softener is simple. A guide is provided to help you step by step, particularly with correctly setting the CO₂ cylinder pressure and optimizing consumption.

    Activated carbon

    Leave the PVC tube and strainer inside the tank, then temporarily cover the top of the tube. Using a funnel, first pour in the flint, then the activated carbon.

    Before screwing on the electromechanical valve, make sure you correctly install the O-ring and the second strainer. Without these components, the tube may rise when you remove the valve.

    RO system

    Be especially gentle when screwing the fittings onto the water inlet and outlets, as the threads are PVC. If a fitting is damaged, you can find compatible parts at specialty stores.

    Installing the membranes in their housings may require some care. Feel free to contact us if you have any difficulty.

    Maintenance

    Maintaining your system’s performance

    Filters and membranes must be replaced regularly to maintain your RO system’s filtration performance.

    PP filter

    Replacement is recommended every 3 months with 24/7 use.

    View the PP filter

    RO membranes

    Replacement is recommended every 2 years with 24/7 use.

    View the membranes

    Warranty

    Equipment built to last

    The manufacturer’s warranty lasts 2 years and covers the entire system under normal equipment use.

    After the warranty expires, we also commit to offering reasonably priced spare parts to make repairs easier and extend your system’s service life.

    Specifications

    Technical specifications

    Performance and equipment

    Specifications Values
    Operating pressure 8 to 14 bars
    Pipe diameters Inlet: 3/4" (20/27) – Outlets: 1/2" (15/21)
    Pre-filter height 20" (50 cm)
    Salt removal rate 99 %
    Pump power supply 230 V / 50 Hz
    Unit power supply 230 V / 50 Hz
    Pressure gauge Glycerin-filled pressure gauge
    Flow meters Inlet and outlet flow meters
    High-pressure pump control Start / stop button for the high-pressure pump
    Pressure monitoring System pressure monitoring with pressure gauges
    Display Real-time display of filtered water conductivity
    Flushing Automatic flushing with the inlet feed water flow
    Control panel Digital control panel
    Pump Vertical multistage pump for 24/7 operation
    Wastewater / recirculation control Wastewater and recirculation pressure control
    Pipes PN-16 PVC pipes
    Recovery rate 50 % to 75 % – 1 liter of wastewater for every 1 to 3 liters of RO water
    Normal operating condition 2,000 ppm
    Frame Stainless steel frame mounted on casters with integrated brakes

    Available models

    Capacities and configurations

    Model Membrane Pump Capacity Dimensions Weight
    OI3000E 2 × Vontron ULP-11-4040 2 kW 9,600 L/j 63 × 73 × 161 cm 75 kg
    OI6000E 4 × Vontron ULP-11-4040 2 kW 19,200 L/j 63 × 73 × 161 cm 80 kg

    Two capacities available: the OI3000E model produces up to 9,600 liters per day, while the OI6000E reaches up to 19,200 liters per day.

    Documents

    Documents and downloads

    Technical documentation for your industrial RO system

    Data sheet

    Review the equipment’s key technical data and specifications.

    Download the data sheet

    User manual

    Find the information you need to operate the system and get started.

    Download the user manual

    Assembly sheet

    Review the assembly and connection instructions for your industrial RO system.

    Download the assembly sheet